Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Intervalo de año de publicación
1.
Pesqui. vet. bras ; 39(11): 923-931, Nov. 2019. tab, graf, ilus
Artículo en Inglés | VETINDEX, LILACS | ID: biblio-1056913

RESUMEN

Few reports have been published regarding the use of ultrasonography as a method of evaluating the normal thyroid gland in horses. For these reasons, this study aimed at determining reliably of the thyroid measurements from the comparison between the left and right thyroid lobes, as well as assessing the contour, format, echotexture and echogenicity of the healthy thyroid by mode-B ultrasonography. Additionally, the equine thyroid vascularization was quali-quantitatively characterized the by Doppler. The sample size initially was determined by the animal selection with advanced age and without volume increase in the neck proximal region. Finally, eleven horses were selected by laboratory test, search of thyroid neoformations by ultrasonography and cytology thyroid. Next, these animals were submitted to thyroid lobes ultrasonographic evaluation. Excellent reproducibility was observed for all measurements obtained. Among the comparisons made between the quantitative parameters of the left and right lobes, it was observed that there was only difference between their respective lengths. Qualitatively, there was a significant variation between the lobes elliptical format in the longitudinal plane of some glands, which oscillated between a rounded and flattened conformation. Thus, we can conclude that the difference between the lobes format of some thyroids can be explained by the significant difference observed between the length of the left and right lobes. Additionally, it was verified that there was no difference between the Doppler quantitative parameters. Therefore, we may suggest that unilateral analysis of the cranial thyroid artery by spectral Doppler can be used to evaluate equine thyroid diffuse disorders.(AU)


Poucas análises foram publicadas com relação ao uso da ultrassonografia como método de avaliação da glândula tireoide hígida em equinos. Alguns trabalhos incluem a determinação das dimensões e características do parênquima. Por essas razões, este estudo teve como objetivo determinar com segurança as medidas tireoidianas a partir da comparação entre o lobo tireoidiano esquerdo e direito, bem como avaliar os contornos, formato, ecotextura e ecogenicidade das glândulas tireoides hígidas pela ultrassonografia em modo B. Além disso, a vascularização da tireoide equina foi caracterizada quali-quantitativamente pela ferramenta Doppler. O tamanho da amostra inicialmente foi determinado pela seleção dos animais com idade avançada e sem aumento de volume na região proximal do pescoço. Por fim, onze equinos foram selecionados por meio de exame laboratorial, pesquisa de neoformações tireoidianas por ultrassonografia e citologia da tireoide. Em seguida, estes animais foram submetidos à avaliação de lobos tireoidianos por ultrassonografia. Observou-se excelente reprodutibilidade em relação a todas as medidas deste estudo. Foram observadas diferenças qualitativas entre os lobos tireoidianos direito e esquerdo. Assim, podemos concluir que tais diferenças entre o formato dos lobos tireoidianos podem ser explicadas pela diferença significativa e/ou tendência observada no parâmetro comprimento entre os respectivos lobos. Além disso, não foi encontrada diferença significativa entre os valores da artéria tireoidiana cranial esquerda em relação aos obtidos na artéria tireoidiana cranial direita, sugerindo que a análise dos valores espectrais do Doppler de uma das artérias tireoidianas craniais possa ser utilizada como método de avaliação de distúrbios difusos da tireoide equina.(AU)


Asunto(s)
Animales , Glándula Tiroides/anatomía & histología , Glándula Tiroides/diagnóstico por imagen , Caballos , Ultrasonografía/veterinaria
2.
Pesqui. vet. bras ; 39(1): 75-84, Jan. 2019. tab, ilus
Artículo en Inglés | LILACS, VETINDEX | ID: biblio-990231

RESUMEN

As age increases, changes in cardiovascular anatomy and physiology occur, even in the absence of disease. Thus, studies of vessel hemodynamics are considered primordial to detect any cardiovascular changes. The objective of this study has been to describe the parameters of B-mode and spectral Doppler ultrasonography in the evaluation of the common carotid arteries of 11 equine and 11 mules, and correlate with age, body mass and neck circumferences. The diameters, intima - media thickness (IMT), resistivity index (RI), pulsatility index (PI), systolic velocity (SV), diastolic velocity (DV), maximum velocity (MV), vascular flow index (VFI), body mass, age, circumference and neck length. Ultrasonographic variables were evaluated in three different region called cranial, middle and caudal. Equine females presented higher values regarding the body mass, age and neck length, as compared to the neck circumferences of the animals, those of the mules were superior. The age of the mules had a positive correlation with the body mass, diameter and neck circumferences, it has a negative correlation between age and vessel diameters. The body mass of the mules had a positive correlation with age and vessel diameters, and with vessel diameters and neck circumferences in equine females. The RI and PI variables had a positive correlation with body mass for mules, and with age for equine females. The DV had a negative correlation with body mass for both equine and mule females. Regarding the variables MV and VFI, age correlated negatively for mules, while it was not significant for equine females. It found a difference between equine females and mules in the correlations performed, with body mass, age, neck circumferences and between B-mode and Doppler ultrasonography variables.(AU)


Com o aumento da idade ocorrem alterações na anatomia e fisiologia cardiovascular, mesmo na ausência de doenças. Assim, os estudos da hemodinâmica dos vasos são considerados primordiais para detectar quaisquer alterações cardiovasculares. Esse trabalho tem como objetivo descrever as variáveis de ultrassonografia modo-B e Doppler espectral na avaliação das artérias carótidas comuns de 11 fêmeas equinas e 11 muares, e correlacionar com idade, massa corpórea e circunferências dos pescoços. Para tais procedimentos foram avaliados os diâmetros, espessura da camada íntima média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD), velocidade máxima (VM), índice de vascularização de fluxo (IVF), massa corpórea, idade, circunferências e comprimentos dos pescoços. As variáveis ultrassonográficas foram avaliadas em três regiões diferentes denominados de crania médio e caudal. As fêmeas equinas apresentaram valores maiores referente ao massa corpórea, idade e comprimento dos pescoços, já em relação às circunferências dos pescoços dos animais, as dos muares foram superiores. A idade dos muares possuiu correlação positiva com a massa corpórea, diâmetro e com as circunferências dos pescoços, com as fêmeas equinas, possui correlação negativa entre idade e os diâmetros dos vasos. A massa corpórea dos muares teve correlação positiva com idade e diâmetros dos vasos, já às fêmeas equinas com diâmetros dos vasos e as circunferências dos pescoços. As variáveis IR e IP tiveram correlação positiva com a massa corpórea para os muares, e com idade para fêmeas equinas. O VD teve correlação negativa com a massa corpórea tanto para as fêmeas equinas quanto nos muares. Já as variáveis VM e IVF, a idade correlacionou negativamente para os muares, enquanto não foi significativo para as fêmeas equinas. Averiguou diferença entre fêmeas equinas e muares nas correlações realizadas, com a massa corpórea, idade, circunferências dos pescoços e entre as variáveis da ultrassonografia modo-B e Doppler.(AU)


Asunto(s)
Animales , Arterias Carótidas/anatomía & histología , Arterias Carótidas/fisiología , Arterias Carótidas/diagnóstico por imagen , Equidae/anatomía & histología , Equidae/fisiología , Ultrasonografía/veterinaria , Ultrasonografía Doppler/veterinaria
3.
Vet Anaesth Analg ; 43(1): 99-108, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25997162

RESUMEN

OBJECTIVE: To examine the relationship between probe tip size and force readings of mechanical nociceptive thresholds (MTs) to identify appropriate probes for horses. STUDY DESIGN: Randomized, crossover study. ANIMALS: Eight adult, mixed-breed horses aged 5-10 years, weighing 268-460 kg. METHODS: Four probe configurations (PCs) were used in random sequence: 1.0 mm diameter (SHARP); 3.2 mm (BLUNT); spring-mounted 1.0 mm (SPRING), and 3 × 2.5 mm (3PIN). A remote-controlled unit on the horse increased force (1.2 N second(-1)) in a pneumatic actuator on the metacarpus. Mean MT for each PC was calculated from 10 readings for each horse. Data were log-transformed for analysis using mixed-effects anova/linear regression (p < 0.05). Variability of data for each PC was assessed using the coefficient of variation (CV). RESULTS: Mean ± standard deviation MTs were: SHARP, 5.6 ± 2.3 N; BLUNT, 11.4 ± 3.4 N; 3PIN, 9.6 ± 4.6 N, and SPRING 6.4 ± 1.8 N. Mean MT for SHARP was significantly lower than for BLUNT (p < 0.001) and 3PIN (p < 0.001), but not different from SPRING (p > 0.05). Mean MT was significantly higher for BLUNT than for 3PIN (p < 0.05) and SPRING (p < 0.001). Mean MT for 3PIN was significantly higher than for SPRING (p < 0.001). Larger contact area PCs produced higher MTs than smaller PCs, but the relationship was not linear. BLUNT (area: 10-fold greater) gave a MT two-fold higher than SHARP. 3PIN (area: 20-fold greater) produced more variable MTs, less than two-fold higher than SHARP. SPRING was similar to SHARP. CVs were: SHARP, 22.9%; BLUNT, 72.3%; 3PIN, 44.2%, and SPRING, 28.7%. CONCLUSIONS AND CLINICAL RELEVANCE: The PC has nonlinear effects on MT. Therefore, it is important to define PC when measuring MT. Smaller probe tips may be preferable as MT data are less variable.


Asunto(s)
Caballos/fisiología , Dolor Postoperatorio/veterinaria , Animales , Fenómenos Biomecánicos , Estudios Cruzados , Caballos/cirugía , Masculino , Nocicepción , Dimensión del Dolor/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...